eluox@yahoo.com         +86 183 4933 8595

Eluox Automation

Eluox ELA10 IEPE Accelerometer

ELA10 IEPE Accelerometer


Dynamic                                                    Value

Axis                                                           Single

Range                                                        +/-10g

Voltage sensitivity                                      500mV/g (+/-10%)

Frequency response (+/-3dB)                    0.25 ... 3700Hz

                                  (+/-10%)                   0.45 ... 1500Hz

                                  (+/-5%)                     0.6 ...700 Hz

Resonance frequency                                > 10kHz

Transverse sensitivity                                < 5% (max.)


Electrical

Excitation Voltage                                      18 -- 30Vdc

Supply current                                            2 -- 10mA

Bias output voltage                                     12 -- 14Vdc


Environmental

Temperature range                                     -55 ... +120 Celsius

Shock limit                                                  2000g peak


Physical

Sensing element                                         PZT ceramics

Sensing element design                              shear

Casing materials                                          316L stainless steel

Connector                                                    2 pin, MIL-C-5015

Mounting hole                                              1/4 - 28 UNF tapped hole

Mounting torque                                           3 -- 5 N-m

Dimenion:                                                     phi-22 x H51 +/-1%

Weight                                                          120gram

-------------------------------------------------------------------------------------------

The above performance specification conform to JJG 233-2008 piezoelectric accelerometer and are typical values, referenced at +24Celsius, 24Vdc supply, 4mA, and 160Hz, unless otherwise noted. Calibration data, traceable to National Institute of Standard and Technology (NIST), is supplied.

The output of the sensor is original vibration signal. And it is suitale for wave profile acquisition. 

Maximum cable length should be less than 30m.

Excitation overload is not permitted.


We are also in the positon to supply IEPE accelerometer with measurement range of +/-50g, +/-500g, etc.

Main features

Ultralow frequency response

Rugged design

Corrusion resistant

500mV/g sensitivity

EMI & RFI shielded